Portable shortwave X-ray flaw detector for steel wire rope core conveyor belt

0537-6280558
Reservation
Detail

Operational Principle

Based on the principle of shortwave X-ray perspective, detection of wire rope pulling, breakage, and rust in conveyor belts is achieved. When adjusting the shortwave ray emission source and the shortwave ray perspective movement angle to be the same as the vulcanization angle of the joint, the user only needs to shake the joystick on the equipment to complete the detection of the conveyor belt joint.


System Function

1. Perform static fixed-point detection of the joints and broken ends of the steel wire rope core conveyor belt through perspective.

2. By relying on the mechanical device of the equipment, users can complete fixed-point detection of a conveyor belt joint without the need to move the equipment.

3. By relying on the mechanical device of the equipment, users can detect any inclination of the steel wire rope core conveyor belt joint.


Characteristic

1. Real time observation is possible without the need for a darkroom or protection.

2. High gain, high sensitivity, high spatial resolution, and easy operation.

3. The lowest radiation dose, safe and reliable, with a simplified structure, small size, light weight, and can be used by hand.

4. It can be connected to video and computer systems according to user requirements, or equipped with a video recording system.

5. The equipment is used to detect the usage of the steel wire rope in the steel wire core conveyor belt, and real-time images are required to be displayed directly from the local display screen.

6. There is a storage unit that can record and store images, and display the recording time; Images and data can be read out by a computer for editing and printing.


Technical Performance

A. Working conditions of X-ray machine: 1. Atmospheric pressure: 700hpa-1060hpa; 2. Environmental temperature:+10-+40 ℃; 3. Relative humidity: 30% -75%

B、 Transportation and storage conditions: 1. Environmental temperature range: -40 ℃ -70 ℃; 2. Relative humidity range: 10% -100%; 3. Atmospheric pressure range: 500hpa-1060hpa

C、 Power supply conditions: Voltage: DC 14.4V; Current: Perspective 2A or 3.5A (continuous)


System Innovation Points

1. The high-voltage current shortwave X-ray perspective part, which has undergone special treatment, is almost radiation free when observed through reflection conversion or when the camera angle does not directly illuminate the human body;

2. A safe and efficient shortwave X-ray perspective system ensures the safety of device use and the clarity of perspective;

3. Convenient mechanical operation device, users can complete fixed-point detection of a conveyor belt joint without moving the equipment.


Applicable Scope

Suitable for non-destructive testing of the entire series (ordinary and with tear resistant steel wire mesh) of steel wire rope core conveyor belts.